If you are looking for a good learning site that can help you to pass the EMC E20-885 exam, IT-Tests.com is the best choice. IT-Tests.com will bring you state-of-the-art skills in the IT industry as well as easily pass the EMC E20-885 exam. We all know that this exam is tough, but it is not impossible if you want to pass it. You can choose learning tools to pass the exam. I suggest you choose IT-Tests.com EMC E20-885 exam questions and answers. I suggest you choose IT-Tests.com EMC E20-885 exam questions and answers. The training not only complete but real wide coverage. The test questions have high degree of simulation. This is the result of many exam practice. . If you want to participate in the EMC E20-885 exam, then select the IT-Tests.com, this is absolutely right choice.
EMC E20-885 is a certification exam to test IT professional knowledge. IT-Tests.com is a website which can help you quickly pass the EMC certification E20-885 exams. Before the exam, you use pertinence training and test exercises and answers that we provide, and in a short time you'll have a lot of harvest.
IT-Tests.com has a huge team of IT experts, who continue to use their knowledge and experience to study a lot of IT certification examination papers of past few years. Their findings of the research is now the product of IT-Tests, therefore IT-Tests's EMC E20-885 practice questions are very similar with the real exam, which can help a lot of people to realize their dreams. IT-Tests.com can ensure you to successfully pass the exam, and you can boldly Add IT-Tests's products to your shopping cart. With IT-Tests.com your dreams can be achieved immediately.
Exam Code: E20-885
Exam Name: EMC (VNX Solutions Expert Exam for Implementation Engineers)
Are you still upset about how to pass EMC certification E20-885 exam? Are you still waiting for the latest information about EMC certification E20-885 exam? IT-Tests.com has come up with the latest training material about EMC certification E20-885 exam. Do you want to pass EMC certification E20-885 exam easily? Please add IT-Tests's EMC certification E20-885 exam practice questions and answers to your cart now! IT-Tests.com has provided part of EMC certification E20-885 exam practice questions and answers for you on www.IT-Tests.com and you can free download as a try. I believe you will be very satisfied with our products. With our products you can easily pass the exam. We promise that if you have used IT-Tests's latest EMC certification E20-885 exam practice questions and answers exam but fail to pass the exam, IT-Tests.com will give you a full refund.
EMC certification E20-885 exam is a rare examination opportunity to improve yourself and it is very valuable in the IT field. There are many IT professionals to participate in this exam. Passing EMC certification E20-885 exam can improve your IT skills. Our IT-Tests.com provide you practice questions about EMC certification E20-885 exam. IT-Tests's professional IT team will provide you with the latest training tools to help you realize their dreams earlier. IT-Tests.com have the best quality and the latest EMC certification E20-885 exam training materials and they can help you pass the EMC certification E20-885 exam successfully.
E20-885 (VNX Solutions Expert Exam for Implementation Engineers) Free Demo Download: http://www.it-tests.com/E20-885.html
NO.1 A customer has an Oracle ASM database on an EMC VNX with FAST Suite enabled. They observe
intermittent performance degradation due to momentary data hot spots caused by bursty transaction rates.
What recommendation would you make to help alleviate these hot spots?
A. Enable Fast VP on the ASM LUNs
B. Modify the ASM rebalance power priority
C. Enable Fast Cache on the ASM LUNs
D. Disable ASM storage management
Answer: C
EMC E20-885 test answers E20-885 certification training E20-885 certification training E20-885
NO.2 A system administrator wants to migrate medical-imaging data stored on an EMC VNX. The host
connects to the VNX via iSCSI. The IP SAN infrastructure has recently been updated to support 1 Gb/10
GB switching. The system administrator wants to maximize data transfer performance. What would you
recommend?
A. Implement 10 Gb/s iSCSI connection using a 9000 byte frame.
B. Use a 4 KB memory page size.
C. Implement 10 Gb/s iSCSI connection using a 2400 byte frame.
D. Increase the write-aside value.
Answer: A
EMC demo E20-885 E20-885 E20-885
NO.3 A customer recently purchased an EMC VNX to be connected to four ESXi 5.0 hosts via FC. Five of the
associated VMs (virtual machines) are running SQL Server 2008 R2. To avoid contention, the customer
wants the VM's database and log drives on separate datastores.
Which ESXi 5.0 feature would satisfy this requirement?
A. Network interface card teaming
B. Virtual Machine Anti-Affinity
C. Raw Device Mappings
D. VMDK Affinity
Answer: B
EMC E20-885 E20-885 certification E20-885 certification training E20-885
NO.4 A Pool used for FAST VP has the following configuration:
Flash drives: 1,000 GB, with 1,000 GB free
SAS drives: 5,000 GB, with 2,500 GB free
NL-SAS drives: 20,000 GB, with 11,500 GB free
The tiering policy is set to Auto. An additional 600 GB of new data is written to the Pool.
What is the data distribution after the data is written?
A. Flash drives: 960 GB free SAS drives: 2,400 GB free NL-SAS drives: 11,040 GB free
B. Flash drives: 400 GB free SAS drives: 2,500 GB free NL-SAS drives: 11,500 GB free
C. Flash drives: 900 GB free SAS drives: 2,000 GB free NL-SAS drives: 11,500 GB free
D. Flash drives: 970 GB free SAS drives: 2,350 GB free NL-SAS drives: 11,080GB free
Answer: A
EMC original questions E20-885 E20-885 dumps E20-885 E20-885 questions
NO.5 A customer plans to connect ESXi 5.0 hosts to a new EMC VNX array. They want to take advantage of
the hardware-assisted locking feature in VAAI. Which is a feature of hardware-assisted locking?
A. Locking at the block level of a logical unit
B. Locking the LUN instead of the block level
C. Accessing a block from multiple hosts at the same time
D. Automatic enabling of safe data caching
Answer: A
EMC original questions E20-885 original questions E20-885 E20-885
NO.6 A customer requests a performance review of their EMC VNX before FAST Cache is implemented.
You notice a dedicated LUN has a write size of 4 KB, and the disks are performing writes of 8 KB. What is
causing this behavior?
A. Coalescing
B. Pre-fetching
C. Flushing
D. Promotion
Answer: A
EMC test questions E20-885 E20-885 practice test E20-885
NO.7 A client has an EMC VNX configured with four storage ports, four 15-drive DAEs (disk array
enclosures) and a total of forty drives (20 NL-SAS and 20 SAS drives). The client is using RAID 5 (4+1)
RAID groups with a traditional LUN configuration.
What is the recommended SAS LCC port configuration for optimal performance?
A. Distribute drives evenly across all ports
B. Distribute drives on all odd ports
C. Distribute drives on all even ports
D. Distribute drives on a single port
Answer: A
EMC answers real questions E20-885 E20-885 test answers E20-885 study guide
NO.8 A customer has two EMC VNX, one at the primary site and the other at a DR site located 100 km away.
The WAN connection between sites is a 100 Mb/s dark fiber link with 4 ms latency.
A previous storage administrator configured the pool LUNs for the file system on thin LUNs. The file
system is growing at a rate of 500 GB per week and is on a VDM. The new storage administrator reports
performance issues with the file system.
What is the most likely reason for the performance issue?
A. Thin LUNs are used for the file system.
B. The WAN link should be upgraded to an eLAN.
C. The VNX system requires an upgrade.
D. The file system has too many concurrent users connected.
Answer: A
EMC certification training E20-885 E20-885 certification training
NO.9 A customer recently upgraded from vSphere v4.x to vSphere v5.0 to benefit from new VMFS-5 features
for their existing DataStore1 ¯ and DataStore2 ¯ datastores on an EMC VNX. A second identically
configured VNX was implemented and the customer created two additional datastores on the new VNX.
After monitoring the environment, the customer notices the VMs on DataStore1 ¯ and DataStore2 ¯
are not using the same sub-block structure as the two new datastores.
What is the reason for this behavior.?
A. The old VMs are on an upgraded VMFS-5 datastore.
B. The old VMs are still running old VMware tools.
C. The new VMFS-5 features need to be licensed and activated.
D. The new VMFS-5 cannot support two VNX storage systems.
Answer: A
EMC E20-885 dumps E20-885 questions E20-885 E20-885 test answers
NO.10 A customer wants to replicate a CIFS environment from a legacy EMC Celerra to a new EMC VNX.
Users are able to access CIFS shares from both arrays. The CIFS shares are on different networks and
replication is not running. The customer wants to make sure there will be no network restrictions
preventing replication between the data movers on two different networks.
What TCP ports should they ask the network team to open?
A. 8888, 8887, 5081
B. 80, 443, 8080
C. 5057, 445, 5087
D. 23, 25, 22
Answer: A
EMC demo E20-885 dumps E20-885 exam prep E20-885
NO.11 A customer has two EMC VNX configured to replicate between sites. Each VNX has dual Control
Stations. The primary Control Station at the source site fails at 6 p.m. and reboots. At 8 p.m., the customer
completes DR testing and observes CIFS replication does not failover to the target site VNX. Why does
CIFS replication not failover to the target VNX during the DR test?
A. The control station of the primary VNX should have been failed back.
B. The control station of the second VNX should have been failed over.
C. The control station of the primary VNX should have IP bounding enabled.
D. The control station of the secondary VNX should have IP bounding enabled.
Answer: A
EMC exam simulations E20-885 E20-885 E20-885 E20-885 certification E20-885
NO.12 A customer has a CIFS DR solution with EMC VNX using a One-to-Many replication topology. The
customer asks you to explain replication behavior under the following conditions:
Production site failover or switchover to a DR site
Replication start and reverse is performed
What would you advise the customer?
A. The original production site remains a One-to-Many replication source for the other remaining DR sites.
B. All remaining replications sessions to the other DR sites are suspended.
C. The original production site goes into cascade mode to remain a replication source for the remaining
DR sites.
D. The DR site becomes the replication source for the remaining DR sites and the original production site
is marked as invalid.
Answer: C
EMC E20-885 E20-885 E20-885
NO.13 Click on the calculator icon in the upper left-hand corner.
A SQL database requires 1,000 I/O per second with 85% reads and 15% writes. If RAID 1/0 is used, what
is the total number of spindles required to generate the required I/O per second?
A. Ten 10K drives
B. Four 15K drives
C. One Flash drive
D. Fourteen 7.2K drives
Answer: A
EMC test questions E20-885 E20-885 certification E20-885 test questions E20-885 exam
NO.14 An administrator is attempting to vMotion a VM from one vSphere ESXi 5.0 host to another. The ESXi
servers are connected to three VNX arrays on the fabric. The vMotion fails. What is the most likely
reason?
A. RDMs are attached to the VM with different host LUN numbers on the ESXi servers.
B. There are active SnapView sessions on the VM preventing the vMotion.
C. RDMs are in physical compatibility mode and not eligible for vMotion.
D. There are active MirrorView sessions on the VM preventing the vMotion.
Answer: A
EMC original questions E20-885 E20-885 E20-885 E20-885 test questions
NO.15 A customer has two identically configured Linux hosts (OS version, memory, CPU) attached to the
same network. One host is NFS-attached and the other is FC-attached to an EMC VNX. Both the NFS file
systems and the SAN LUNs are created from four RAID 5 (4+1) RAID groups. LUNs are not shared
between file and block and each host generates the same size I/O.
The customer reports the FC-attached host is able to achieve much greater throughput than the
NFS-attached host.
What is the source of the performance difference between the file and block configurations?
A. FC encapsulation overhead
B. Host Patch levels
C. Ethernet Network
D. NFS version
Answer: C
EMC E20-885 pdf E20-885 braindump
NO.16 A customer requires an asynchronous DR solution for an NFS-only client environment. The customer
wants the solution to be simple to implement. It was recommended they create a single NIS domain, and
use several NIS servers to provide centralized authentication to the NFS clients at both the source and
destination sites. The customer asks you whether they should consider using VDMs in this environment.
What do you advise?
A. VDMs would offer no advantages to this environment.
B. VDMs allow VMWare integration of NFS service environments.
C. VDMs eliminate the need for Usermapper in NFS environments.
D. VDMs allow for assignment of specific CPUs to a NFS server.
Answer: A
EMC E20-885 E20-885 practice test E20-885 exam simulations
NO.17 A customer has two identically configured Linux hosts (OS version, memory, CPU) attached to the
same network. One host is NFS-attached and the other is FC-attached to an EMC VNX. Both the NFS file
systems and the SAN LUNs are created from four RAID 5 (4+1) RAID groups. LUNs are not shared
between file and block.
The customer reports NFS-attached host is able to achieve much greater throughput via NFSv4 versus
the FC-attached host.
What is the source of the performance difference between the file and block configurations?
A. FC encapsulation overhead
B. I/O size
C. Host Patch levels
D. NFS version
Answer: B
EMC certification training E20-885 E20-885 exam
NO.18 You are planning a CIFS DR solution for two existing EMC VNX. Each VNX has dual Control Stations.
Each VNX is also configured for a RecoverPoint protection solution on other VNX LUNs that are non-file
related. What recommendation would you give the customer concerning the CIFS DR solution?
A. Configure IP aliasing on the Control Stations for both source and destination VNX systems before
configuring VNX Replicator
B. Configure IP aliasing on the Control Stations for both source and destination VNX systems after
configuring VNX Replicator
C. Configure IP aliasing on the source VNX system Control Stations before configuring VNX Replicator,
and then configure IP aliasing on the destination VNX system Control Stations after configuring VNX
Replicator.
D. Configure IP aliasing on the source VNX system Control Stations before configuring VNX Replicator
and use RecoverPoint to provide protection of the source VNX Control Stations to the destination VNX.
Answer: A
EMC answers real questions E20-885 answers real questions E20-885 E20-885
NO.19 A customer has a Windows-only environment connected to an EMC VNX for File at their main campus
site. The customer plans to install a new EMC VNX at a remote branch office site. The new VNX will be
used to implement a DR solution for their main campus VNX using several deduplicated file systems
shared and available to clients via CIFS.
Which solution do you recommend to the customer?
A. Use VNX Replicator to replicate the VNX VDMs and associated file systems from the main campus site
to the VNX system at the branch office site to provide an asynchronous DR solution.
B. Use VNX Replicator to replicate the VNX VDMs and associated file systems from the main campus site
to the VNX system at the branch office site to provide a synchronous DR solution.
C. Use VNX SAN Copy to replicate the VNX block devices associated with the VNX file systems from the
main campus site to the VNX system at the branch office site to provide a synchronous DR solution.
D. Use VNX MirrorView/A to replicate the VNX block devices associated with the VNX file systems from
the main campus site to the VNX system at the branch office site to provide an asynchronous DR solution.
Answer: A
EMC pdf E20-885 E20-885 certification E20-885 study guide E20-885
NO.20 A storage administrator reports they are unable configure SAN Copy connections between two VNX.
The required cabling is in place and zoning is correct, but the SP connections still do not appear in
Unisphere Manager. What could have caused this issue?
A. SAN Copy is not installed on both VNX arrays.
B. SAN Copy is only licensed for local copies.
C. The SP ports are already being used by hosts.
D. Both VNX arrays are not in the same domain.
Answer: D
EMC E20-885 study guide E20-885 pdf E20-885 E20-885 exam
Are you still worrying about how to safely pass EMC certification E20-885 exams? Do you have thought to select a specific training? Choosing a good training can effectively help you quickly consolidate a lot of IT knowledge, so you can be well ready for EMC certification E20-885 exam. IT-Tests's expert team used their experience and knowledge unremitting efforts to do research of the previous years exam, and finally have developed the best pertinence training program about EMC certification E20-885 exam. Our training program can effectively help you have a good preparation for EMC certification E20-885 exam. IT-Tests's training program will be your best choice.
没有评论:
发表评论